Process chillers keep lasers, analytical instruments, reactors, and pilot equipment at temperature. Recirculating baths and circulators hold a bath within a fraction of a degree. When one fails, the instrument it cools stops, and the downtime is usually worth more than the chiller. We service portable and rack chillers, circulators, and baths from the major makers.

  • Since 1977
  • Huntington Beach, CA
  • ISO 9001:2015 certified
  • Factory Authorized Service Center
  • NIST-traceable calibration
Illustration of process chiller, Scientific Refrigeration blueprint style

Chiller down and the instrument heating up? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.

What we repair and service

  • Recirculating and process chillers

    Air- and water-cooled chillers from benchtop to skid-mounted, including pump, heat exchanger, and refrigeration circuit work.

  • Heating and refrigerated circulators

    Bath circulators and thermostats used for calibration, viscometry, and reaction control.

  • Water baths and cold traps

    General-purpose and precision baths, and refrigerated cold traps on vacuum systems.

  • Controls and fluid systems

    Controllers, flow and pressure switches, filters, fluid conditioning, and the plumbing to the instrument.

What we’re called for

Fluid runs low or grows algae and flow drops until the instrument trips. A dirty condenser raises head pressure and the compressor short-cycles. Pump seals wear and the reservoir empties onto the floor. A deadband set too tight keeps the compressor cycling all day. Most chiller calls are fluid, filter, and condenser problems that a maintenance visit prevents; the rest are refrigeration repairs we do every week.

What a repair visit includes

  • Diagnosis on site

    Fluid level and condition, filters and strainers, condenser airflow, and pump pressure are ruled out first, because most chiller calls are not the compressor.

  • The repair

    Pumps and seals, flow and pressure switches, filters, fluid, condensers and fans, controllers, and the refrigeration circuit when it is the real fault.

  • Verification before we leave

    Flow, pressure, and temperature verified at the instrument connection, and the display checked against a reference.

  • The record, and a straight answer

    A written record of what failed and what was done, and a plain repair-or-replace recommendation when a unit is past its useful life.

Response, rentals, and emergencies

A chiller that stops a laser or a mass spectrometer is a priority call, and we coordinate the shutdown with your instrument service provider. We do not rent chillers.

Heat transfer fluids and operating range

A chiller’s operating range depends on the heat transfer fluid it runs. Water chillers stay above freezing. Glycol-based fluids extend that range below 0°C, and specialty silicone, synthetic, and perfluorinated fluids are engineered for much lower temperatures. Below are published operating ranges for some of the most widely used heat transfer fluids.

  • Water

    Type
    Water
    Published operating range
    Above 0°C (32°F)
  • DOWFROST™

    Type
    Propylene glycol
    Published operating range
    -18 to 121°C (0 to 250°F); freezing point -51°C (-60°F) when diluted to 60%
  • DOWFROST™ HD

    Type
    Propylene glycol
    Published operating range
    -45 to 160°C (-49 to 320°F)
  • Dynalene® HC series

    Type
    Potassium formate, water based
    Published operating range
    From -10°C (14°F) for HC-10 down to -50°C (-58°F) for HC-50, up to 218°C (425°F) in closed systems
  • SYLTHERM™ 800

    Type
    Silicone
    Published operating range
    -40 to 400°C (-40 to 750°F)
  • SYLTHERM™ HF

    Type
    Silicone
    Published operating range
    -73 to 260°C (-100 to 500°F)
  • SYLTHERM™ XLT

    Type
    Silicone
    Published operating range
    -100 to 260°C (-150 to 500°F)
  • THERMINOL® D-12

    Type
    Synthetic hydrocarbon
    Published operating range
    -94 to 190°C (-137 to 374°F)
  • Galden® HT110

    Type
    Perfluoropolyether (PFPE)
    Published operating range
    -60 to 110°C (-76 to 230°F)
  • Galden® HT135

    Type
    Perfluoropolyether (PFPE)
    Published operating range
    -70 to 135°C (-94 to 275°F)
  • Galden® HT170

    Type
    Perfluoropolyether (PFPE)
    Published operating range
    -30 to 170°C (-22 to 338°F)

Ranges shown are manufacturer-published figures and may vary by grade, concentration, and system design. Published fluid ranges change as manufacturers test and revise their products, so confirm current specifications with the fluid manufacturer before you commit to a fluid. Your chiller’s own rated range also limits what any fluid can achieve; check the fluid against it. Knowing your application is essential to choosing the right fluid and the right chiller for your process. Not sure which fluid fits your system? Call us.

Preventative maintenance that pays for itself

A chiller PM is a condenser cleaning, a fluid change or treatment, a filter and strainer check, a look at pump pressure and flow, and a verification of the temperature display. For equipment that cools a laser or a mass spectrometer, that visit protects an instrument worth many times the chiller.

Brands

Chillers & circulators brands we see most

Linked brands have their own page. Not on the list? Ask. We service most makes and models.

Where

Where we service chillers & circulators

Ten Southern California counties from our Huntington Beach headquarters, and beyond by arrangement.

Los Angeles, Orange, Riverside, San Bernardino, San Diego, and Ventura counties are our core area. Santa Barbara, San Luis Obispo, Kern, and Imperial counties are on a regular route. Equipment that is already down jumps the queue, and our line is answered 24/7.

Outside Southern California we work by arrangement for contract and long-standing customers, and we say plainly what we can do and how soon.

Also from one team

  • Service & Repair

    Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.

  • Preventative Maintenance

    Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.

  • Equipment Rental

    New and used rental units, including 24-hour emergency availability when a unit goes down.

Chillers & circulators FAQs

Common questions

Our chiller short-cycles. What is the usual cause?

Check the simple things first: a dirty condenser, low fluid, or a deadband set too tight. We rule those out before diagnosing the compressor, which is rarely the culprit.

Can you service a chiller that cools a laser or an analytical instrument?

Yes. We work on the chiller and its fluid loop up to the instrument connection, and we coordinate shutdowns with your instrument service provider when needed.

DOWFROST™ and SYLTHERM™ are trademarks of The Dow Chemical Company. Dynalene® is a registered trademark of Dynalene, Inc. THERMINOL® is a registered trademark of Eastman Chemical Company. Galden® is a registered trademark of Syensqo. SciFrig is not affiliated with these companies.

Ready when you are

Chillers & circulators giving you trouble?

Request service online in under a minute, or call. Our line is answered 24/7.

24/7 emergency service · Dispatch confirms every request by phone.

Call nowRequest service

Request service

A few quick questions, then a dispatcher calls you to confirm.

What do you need?

Service type

Equipment failing right now? Don’t wait for a callback. 24/7 emergency service, and the line is answered 24/7.