Service & Repair
Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.
Cryogenic & LN2 storage · Repair & service
Below -130°C the work changes. Cryogenic freezers, liquid-nitrogen dewars with auto-fill, and the level controllers and alarms that watch them protect cell lines and biologics that cannot be replaced. We service the mechanical cryogenic freezers, the LN2 supply and controls, and the monitoring that ties them together.
LN2 freezer alarming or level dropping? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.
-150°C class freezers that use compressors rather than liquid nitrogen, with their own cascade and control systems.
Vapor-phase and liquid-phase storage with auto-fill valves, level sensors, and lid heaters.
Controllers, LN2 level and temperature probes, and the remote alarm and data connections your monitoring depends on.
Transfer hoses, solenoid valves, and vacuum-jacketed lines between the supply tank and the freezer.
An auto-fill valve sticks and the tank either overfills or runs dry. A level sensor ices and reports a level that is not there. A vacuum-jacketed dewar loses its vacuum and starts sweating and consuming nitrogen fast. On mechanical units, the same cascade faults as a ULT apply, at temperatures where a warm-up is measured in minutes. Monitoring that is tested on a schedule catches these before the inventory does.
We separate the fill system, the vessel, and the controls, because a dry tank can be a stuck valve, a lying level sensor, or a dewar that has lost its vacuum, and each has a different fix. Mechanical units get the same stage-by-stage diagnosis as a ULT.
Auto-fill valves and solenoids, level and temperature sensors, lid heaters, controllers, transfer hoses and vacuum-jacketed lines, and cascade components on mechanical cryogenic freezers.
Fill cycle run and watched, alarm points and backup power tested, and remote notification confirmed to reach the people on call.
A written record of what failed and what was done, and a plain repair-or-replace recommendation when a unit is past its useful life.
A warm-up at -150°C is measured in minutes, so call first and keep the lid closed. Our rental fleet does not include cryogenic units; we help you plan the move to a backup vessel or dewar while the repair is made.
We work on the controllers and sensors that manage fill cycles and alarms, verify alarm points and backup power, and confirm that remote notifications reach the people on call. Where a controller line is obsolete, we can advise on retrofit options.
Brands
Linked brands have their own page. Not on the list? Ask. We service most makes and models.
Guides
Written by our technicians: what to check, what the numbers mean, and when to call.
The checklist behind a preventative maintenance visit on a lab refrigerator, freezer, or ULT freezer: each task, how often it is done, and which ones you can do in-house.
How to write a freezer alarm response plan that works at 3 a.m.: who is called, what they check, when product moves, and when to call for a rental.
What separates scientific refrigeration from a kitchen fridge, where labs and hospitals rely on it, and how the equipment breaks down by temperature range.
Where
Ten Southern California counties from our Huntington Beach headquarters, and beyond by arrangement.
Los Angeles, Orange, Riverside, San Bernardino, San Diego, and Ventura counties are our core area. Santa Barbara, San Luis Obispo, Kern, and Imperial counties are on a regular route. Equipment that is already down jumps the queue, and our line is answered 24/7.
Outside Southern California we work by arrangement for contract and long-standing customers, and we say plainly what we can do and how soon.
Also from one team
Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.
Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.
NIST-traceable calibration, IQ / OQ / PQ validation, and the certificates your auditors ask for.
Cryogenic & LN2 storage FAQs
Yes. Fill valves, level sensors, controllers, and the supply plumbing between the tank and the freezer, plus alarm verification.
Usually a loss of vacuum in the jacket. The dewar will consume nitrogen quickly and the hold time drops. Move the inventory if you can and call us to evaluate the vessel.
Ready when you are
Request service online in under a minute, or call. Our line is answered 24/7.
24/7 emergency service · Dispatch confirms every request by phone.