Blood Bank Refrigerators, Plasma Freezers & Platelet Incubators
Blood bank refrigerators, plasma freezers, and platelet incubators, calibrated for AABB and FDA records.
Compliance-grade documentation
When your equipment holds vaccines, samples, reagents, or compounds that have to stay within spec, “it seems fine” isn’t documentation. We calibrate against NIST-traceable references, run full IQ/OQ/PQ validation, and hand you the traceable records your audits and quality systems require.

Equipment failing right now? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.
Calibration checks a unit’s sensor and display against a reference instrument and documents the result. Our references are NIST-traceable, so the numbers on your certificate connect through an unbroken chain to a recognized national standard. That is the traceability auditors and pharmacy boards expect to see.
A single-point check at setpoint, or multiple points across the operating range for equipment that works across it.
Names the reference instrument and its traceability, the points checked, and the result, so the record stands on its own in an audit.
Commonly annual, more often for critical or regulated equipment. Your quality program sets the interval; we keep it.
Every validation is documented and built around your facility’s requirements and the standards you answer to. We draft the protocol and you approve it; your quality program owns the requirements.
Verifies each unit is installed and configured to manufacturer specification, with complete documentation of as-installed conditions.
Confirms the equipment performs correctly across its full operating range rather than at setpoint alone.
Demonstrates consistent, repeatable performance under real-world load and use conditions.
Distributed sensors record the actual conditions at every shelf, usually as the core of OQ and PQ for a storage unit.
Proves that high and low alarms trigger and report, and that CO2 or LN2 backup opens when it should, so a failure is caught before the product is.
Laboratories, hospitals, pharmacies, pharmaceutical and biotech facilities, and any operation running temperature-sensitive equipment under regulatory or quality-system requirements. If you’re preparing for an audit or standing up new equipment, this is where it starts. The same goes for maintaining an existing compliance program.
By equipment
Every class of equipment fails in its own way. Pick yours for what we service, what goes wrong, and which brands we see most.
Blood bank refrigerators, plasma freezers, and platelet incubators, calibrated for AABB and FDA records.
Process chillers, circulators, and water baths that keep lasers, instruments, and reactors at temperature.
Mechanical cryogenic freezers, LN2 dewars, auto-fill systems, level controllers, and alarms.
Stability chambers and environmental test chambers for pharmaceutical, food, aerospace, automotive, and materials testing: repair, humidity systems, controller retrofits, and mapping.
Collector refrigeration, vacuum pumps, controls, and calibration for benchtop and console freeze dryers.
Medical-grade ice machines and dispensers: mechanical service plus scheduled cleaning and sanitizing.
CO2, refrigerated, BOD, and shaking incubators plus growth chambers, with temperature and CO2 calibration.
Drying, sterilizing, and industrial ovens and furnaces: uniformity surveys, repairs, and controller retrofits.
Pharmacy, vaccine, reagent, and chromatography refrigerators held to 2°C to 8°C and documented for inspection.
Reagent, enzyme, and sample freezers from -20°C to -40°C: repair, defrost systems, gaskets, and calibration.
The refrigeration system inside refrigerated centrifuges: compressor, condenser, and chamber control.
Cascade and Stirling -80°C freezers: repair, PM, calibration, CO2/LN2 backup, and rentals while yours is down.
Walk-in coolers and freezers, environmental rooms, and warm rooms: repair, mapping, and emergency response.
Calibration & Validation FAQs
Yes. Our reference instruments are NIST-traceable, so results tie back to a recognized national standard, and the certificate shows the chain.
It depends on the number and type of units and the depth of qualification required. We scope each engagement up front so you know timing and deliverables before we start.
Yes. Audit readiness is exactly what calibration certificates, validation, and the documentation package are for.
Yes. Calibration is often done on the same visit as preventative maintenance and can be written into the program, which saves a trip and keeps the records together.
Also from one team
Multi-point mapping studies that document real conditions across the entire chamber.
Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.
Remote monitoring installed and serviced, CO2 and LN2 backup fitted and tested, battery backup load-tested.
Ready when you are
24/7 emergency service · Dispatch confirms every request by phone.