Skip to main content

Compliance-grade documentation

Calibration, certification & validation

When your equipment holds vaccines, samples, reagents, or compounds that have to stay within spec, “it seems fine” isn’t documentation. We calibrate against NIST-traceable references, run full IQ/OQ/PQ validation, and hand you the traceable records your audits and quality systems require.

  • Since 1977
  • Huntington Beach, CA
  • ISO 9001:2015 certified
  • Factory Authorized Service Center
  • NIST-traceable calibration
Scientific Refrigeration technician recording readings on a clipboard beside an open laboratory refrigerator

Equipment failing right now? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.

NIST-traceable calibration

Calibration checks a unit’s sensor and display against a reference instrument and documents the result. Our references are NIST-traceable, so the numbers on your certificate connect through an unbroken chain to a recognized national standard. That is the traceability auditors and pharmacy boards expect to see.

  • Single or multi-point

    A single-point check at setpoint, or multiple points across the operating range for equipment that works across it.

  • The certificate

    Names the reference instrument and its traceability, the points checked, and the result, so the record stands on its own in an audit.

  • On a schedule

    Commonly annual, more often for critical or regulated equipment. Your quality program sets the interval; we keep it.

What validation covers

Every validation is documented and built around your facility’s requirements and the standards you answer to. We draft the protocol and you approve it; your quality program owns the requirements.

  • Installation Qualification (IQ)

    Verifies each unit is installed and configured to manufacturer specification, with complete documentation of as-installed conditions.

  • Operational Qualification (OQ)

    Confirms the equipment performs correctly across its full operating range rather than at setpoint alone.

  • Performance Qualification (PQ)

    Demonstrates consistent, repeatable performance under real-world load and use conditions.

  • Temperature mapping

    Distributed sensors record the actual conditions at every shelf, usually as the core of OQ and PQ for a storage unit.

  • Alarm and backup testing

    Proves that high and low alarms trigger and report, and that CO2 or LN2 backup opens when it should, so a failure is caught before the product is.

Temperature mapping studies

Who this is for

Laboratories, hospitals, pharmacies, pharmaceutical and biotech facilities, and any operation running temperature-sensitive equipment under regulatory or quality-system requirements. If you’re preparing for an audit or standing up new equipment, this is where it starts. The same goes for maintaining an existing compliance program.

By equipment

Repair & service by equipment type

Every class of equipment fails in its own way. Pick yours for what we service, what goes wrong, and which brands we see most.

Calibration & Validation FAQs

Common questions

Is your calibration NIST-traceable?

Yes. Our reference instruments are NIST-traceable, so results tie back to a recognized national standard, and the certificate shows the chain.

How long does a validation take?

It depends on the number and type of units and the depth of qualification required. We scope each engagement up front so you know timing and deliverables before we start.

Can you help us prepare for an audit?

Yes. Audit readiness is exactly what calibration certificates, validation, and the documentation package are for.

Can calibration be bundled with maintenance?

Yes. Calibration is often done on the same visit as preventative maintenance and can be written into the program, which saves a trip and keeps the records together.

Also from one team

  • Temperature Mapping

    Multi-point mapping studies that document real conditions across the entire chamber.

  • Preventative Maintenance

    Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.

  • Monitoring & Backup Systems

    Remote monitoring installed and serviced, CO2 and LN2 backup fitted and tested, battery backup load-tested.

Ready when you are

Need documentation for an upcoming audit?

24/7 emergency service · Dispatch confirms every request by phone.

Call nowRequest service

Request service

A few quick questions, then a dispatcher calls you to confirm.

What do you need?

Service type

Equipment failing right now? Don’t wait for a callback. 24/7 emergency service, and the line is answered 24/7.