Service & Repair
Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.
CO2 & refrigerated incubators · Repair & service
CO2 incubators, refrigerated and BOD incubators, shaking incubators, and plant growth chambers all do one thing: hold a living process at a temperature it can tolerate. Drift, contamination, and a CO2 sensor that reads wrong all cost time you cannot get back. We service the refrigeration, heating, gas control, and humidity in all of them.
CO2 incubator out of range? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.
Cell culture incubators with CO2, O2, and humidity control, including sensor calibration and decontamination cycles.
Units that cool as well as heat, for microbiology, BOD testing, and low-temperature culture.
Heated incubators and orbital shakers, including drive and temperature-control repairs.
Light, temperature, and humidity control for growth studies and insect rearing.
A CO2 sensor drifts and the medium's pH follows it. A door gasket or humidity pan lets the chamber dry out. On refrigerated incubators, the same compressor and condenser problems as any refrigerator apply, with the added risk that a heating element and a cooling circuit fight each other when a controller misreads. Contamination often traces back to a humidity pan or a fan wheel nobody has cleaned.
We check CO2 with a calibrated reference analyzer, temperature against a reference probe, and on refrigerated units the compressor, condenser, and fan before touching the controller.
CO2 and O2 sensors, heater elements and relays, door gaskets, humidity pans and fan wheels, controllers, and the compressor and condenser on refrigerated and BOD incubators.
Temperature and CO2 verified after the repair, uniformity checked where your protocol requires it, and the visit documented so a reviewer can see the incubator was in control.
A written record of what failed and what was done, and a plain repair-or-replace recommendation when a unit is past its useful life.
A culture incubator out of range is a same-call priority. We do not rent incubators; we tell you plainly whether the unit can be stabilized on the spot or whether cultures should move.
We calibrate temperature and CO2 against traceable references, verify uniformity where your protocol requires it, and document the visit so a reviewer can see the incubator was in control when the work was done.
Brands
Linked brands have their own page. Not on the list? Ask. We service most makes and models.
Guides
Written by our technicians: what to check, what the numbers mean, and when to call.
Keeping a CO2 incubator at 37°C and the right gas mix: cleaning that prevents contamination, calibrating temperature and CO2, and recovering after a failure.
Calibration, validation, and temperature mapping mean different things. What each one proves, and which one your auditor is actually asking for.
What a temperature mapping study involves, what to decide before the probes go in, and how to prepare the unit and paperwork so it passes first time.
Where
Ten Southern California counties from our Huntington Beach headquarters, and beyond by arrangement.
Los Angeles, Orange, Riverside, San Bernardino, San Diego, and Ventura counties are our core area. Santa Barbara, San Luis Obispo, Kern, and Imperial counties are on a regular route. Equipment that is already down jumps the queue, and our line is answered 24/7.
Outside Southern California we work by arrangement for contract and long-standing customers, and we say plainly what we can do and how soon.
Also from one team
Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.
Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.
NIST-traceable calibration, IQ / OQ / PQ validation, and the certificates your auditors ask for.
CO2 & refrigerated incubators FAQs
Yes. We verify CO2 with a calibrated reference analyzer and adjust the incubator's sensor, along with temperature and, where fitted, humidity.
It can be, but a swing is more often a refrigeration or airflow issue: a dirty condenser, a weak compressor, or a slow fan. We check all three before touching the controller.
Ready when you are
Request service online in under a minute, or call. Our line is answered 24/7.
24/7 emergency service · Dispatch confirms every request by phone.