Skip to main content

CO2 & refrigerated incubators · Repair & service

CO2 & Refrigerated Incubator Repair & Calibration

CO2 incubators, refrigerated and BOD incubators, shaking incubators, and plant growth chambers all do one thing: hold a living process at a temperature it can tolerate. Drift, contamination, and a CO2 sensor that reads wrong all cost time you cannot get back. We service the refrigeration, heating, gas control, and humidity in all of them.

  • Since 1977
  • Huntington Beach, CA
  • ISO 9001:2015 certified
  • Factory Authorized Service Center
  • NIST-traceable calibration
Illustration of laboratory incubators, Scientific Refrigeration blueprint style

CO2 incubator out of range? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.

What we repair and service

  • CO2 and multigas incubators

    Cell culture incubators with CO2, O2, and humidity control, including sensor calibration and decontamination cycles.

  • Refrigerated and BOD incubators

    Units that cool as well as heat, for microbiology, BOD testing, and low-temperature culture.

  • Shaking and general-purpose incubators

    Heated incubators and orbital shakers, including drive and temperature-control repairs.

  • Plant growth chambers

    Light, temperature, and humidity control for growth studies and insect rearing.

What we’re called for

A CO2 sensor drifts and the medium's pH follows it. A door gasket or humidity pan lets the chamber dry out. On refrigerated incubators, the same compressor and condenser problems as any refrigerator apply, with the added risk that a heating element and a cooling circuit fight each other when a controller misreads. Contamination often traces back to a humidity pan or a fan wheel nobody has cleaned.

What a repair visit includes

  • Diagnosis on site

    We check CO2 with a calibrated reference analyzer, temperature against a reference probe, and on refrigerated units the compressor, condenser, and fan before touching the controller.

  • The repair

    CO2 and O2 sensors, heater elements and relays, door gaskets, humidity pans and fan wheels, controllers, and the compressor and condenser on refrigerated and BOD incubators.

  • Verification before we leave

    Temperature and CO2 verified after the repair, uniformity checked where your protocol requires it, and the visit documented so a reviewer can see the incubator was in control.

  • The record, and a straight answer

    A written record of what failed and what was done, and a plain repair-or-replace recommendation when a unit is past its useful life.

Response, rentals, and emergencies

A culture incubator out of range is a same-call priority. We do not rent incubators; we tell you plainly whether the unit can be stabilized on the spot or whether cultures should move.

Calibration and documentation

We calibrate temperature and CO2 against traceable references, verify uniformity where your protocol requires it, and document the visit so a reviewer can see the incubator was in control when the work was done.

Brands

CO2 & refrigerated incubators brands we see most

Linked brands have their own page. Not on the list? Ask. We service most makes and models.

Guides

Reading on co2 & refrigerated incubators

Written by our technicians: what to check, what the numbers mean, and when to call.

Where

Where we service co2 & refrigerated incubators

Ten Southern California counties from our Huntington Beach headquarters, and beyond by arrangement.

Los Angeles, Orange, Riverside, San Bernardino, San Diego, and Ventura counties are our core area. Santa Barbara, San Luis Obispo, Kern, and Imperial counties are on a regular route. Equipment that is already down jumps the queue, and our line is answered 24/7.

Outside Southern California we work by arrangement for contract and long-standing customers, and we say plainly what we can do and how soon.

Also from one team

  • Service & Repair

    Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.

  • Preventative Maintenance

    Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.

  • Calibration & Validation

    NIST-traceable calibration, IQ / OQ / PQ validation, and the certificates your auditors ask for.

CO2 & refrigerated incubators FAQs

Common questions

Do you calibrate CO2 as well as temperature?

Yes. We verify CO2 with a calibrated reference analyzer and adjust the incubator's sensor, along with temperature and, where fitted, humidity.

Our refrigerated incubator swings several degrees. Is that a controller problem?

It can be, but a swing is more often a refrigeration or airflow issue: a dirty condenser, a weak compressor, or a slow fan. We check all three before touching the controller.

Ready when you are

CO2 & refrigerated incubators giving you trouble?

Request service online in under a minute, or call. Our line is answered 24/7.

24/7 emergency service · Dispatch confirms every request by phone.

Call nowRequest service

Request service

A few quick questions, then a dispatcher calls you to confirm.

What do you need?

Service type

Equipment failing right now? Don’t wait for a callback. 24/7 emergency service, and the line is answered 24/7.