Calibration & Validation
NIST-traceable calibration, IQ / OQ / PQ validation, and the certificates your auditors ask for.
Blood bank equipment · Repair & service
Transfusion services run on three temperatures that cannot slip: 1°C to 6°C for red cells, -18°C or colder for plasma, and 20 to 24°C with continuous gentle agitation for platelets. We service the refrigerators, freezers, incubators, and agitators that hold them, to the standards AABB and FDA inspectors expect to see documented.
Blood bank refrigerator alarming right now? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.
Upright and undercounter units with chart recorders, audible and remote alarms, and uniformity tight enough for 1°C to 6°C storage.
-30°C and -40°C plasma storage, including manual-defrost units where frost management is part of the maintenance.
Platelets require continuous gentle agitation at 20 to 24°C. Other room-temperature components, such as granulocytes and thawed cryoprecipitate, are stored at the same temperature but should not be agitated. We service the incubator and the agitator drive that has to run without stopping.
Water-bath and dry thawers, and blast or contact freezers used to bring plasma down on schedule.
A blood bank refrigerator is judged on uniformity and recovery, not just setpoint. Heavy door traffic packs frost into the gasket and inner-door seals, longer compressor runs follow, and the top shelf drifts away from the bottom one. Chart recorders need pens, paper, and calibration. Alarm setpoints and battery backup have to be tested, not assumed. We check all of it on every visit and document what we found.
A blood bank unit is judged on uniformity and recovery, so we look at door traffic, gasket condition, and shelf-to-shelf spread as well as the setpoint, and we check the recorder against the probe.
Compressors, evaporator and condenser fans, gaskets and inner-door seals, chart recorder drives and pens, alarm boards and batteries, and platelet agitator drives and controls.
Alarm activation points verified, the chart recorder and probe calibrated against a NIST-traceable reference after the repair, and uniformity confirmed where your SOP requires it.
A written record of what failed and what was done, and a plain repair-or-replace recommendation when a unit is past its useful life.
A blood bank refrigerator alarming or a platelet agitator that has stopped is prioritized as an emergency. Rental blood bank refrigerators and plasma freezers are available so inventory moves once.
We calibrate probes and recorders against NIST-traceable references, verify alarm activation points, and provide certificates and reports formatted for your quality system. When an inspector asks how you know the unit was in range, the answer is in your file.
Brands
Linked brands have their own page. Not on the list? Ask. We service most makes and models.
Guides
Written by our technicians: what to check, what the numbers mean, and when to call.
What blood bank refrigerators, plasma freezers, and platelet incubators have to do that ordinary lab units do not, and the records an inspector expects to see.
Calibration, validation, and temperature mapping mean different things. What each one proves, and which one your auditor is actually asking for.
The checklist behind a preventative maintenance visit on a lab refrigerator, freezer, or ULT freezer: each task, how often it is done, and which ones you can do in-house.
Where
Ten Southern California counties from our Huntington Beach headquarters, and beyond by arrangement.
Los Angeles, Orange, Riverside, San Bernardino, San Diego, and Ventura counties are our core area. Santa Barbara, San Luis Obispo, Kern, and Imperial counties are on a regular route. Equipment that is already down jumps the queue, and our line is answered 24/7.
Outside Southern California we work by arrangement for contract and long-standing customers, and we say plainly what we can do and how soon.
Also from one team
NIST-traceable calibration, IQ / OQ / PQ validation, and the certificates your auditors ask for.
Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.
Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.
Blood bank equipment FAQs
Yes. We calibrate temperature probes, displays, and chart recorders against NIST-traceable references and verify alarm activation, with certificates your AABB and FDA documentation can rely on.
Call us: a stopped agitator is a regulatory event, not a nuisance. We prioritize blood bank calls and carry common drive and control parts.
Yes, and we can schedule defrost and gasket work so it lands when your inventory is low.
Ready when you are
Request service online in under a minute, or call. Our line is answered 24/7.
24/7 emergency service · Dispatch confirms every request by phone.