Skip to main content

Blood bank equipment · Repair & service

Blood Bank Refrigerator & Plasma Freezer Repair

Transfusion services run on three temperatures that cannot slip: 1°C to 6°C for red cells, -18°C or colder for plasma, and 20 to 24°C with continuous gentle agitation for platelets. We service the refrigerators, freezers, incubators, and agitators that hold them, to the standards AABB and FDA inspectors expect to see documented.

  • Since 1977
  • Huntington Beach, CA
  • ISO 9001:2015 certified
  • Factory Authorized Service Center
  • NIST-traceable calibration
Illustration of blood bank refrigeration, Scientific Refrigeration blueprint style

Blood bank refrigerator alarming right now? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.

What we repair and service

  • Blood bank refrigerators

    Upright and undercounter units with chart recorders, audible and remote alarms, and uniformity tight enough for 1°C to 6°C storage.

  • Plasma freezers

    -30°C and -40°C plasma storage, including manual-defrost units where frost management is part of the maintenance.

  • Platelet incubators and agitators

    Platelets require continuous gentle agitation at 20 to 24°C. Other room-temperature components, such as granulocytes and thawed cryoprecipitate, are stored at the same temperature but should not be agitated. We service the incubator and the agitator drive that has to run without stopping.

  • Plasma thawers and rapid freezers

    Water-bath and dry thawers, and blast or contact freezers used to bring plasma down on schedule.

Why blood bank units get special attention

A blood bank refrigerator is judged on uniformity and recovery, not just setpoint. Heavy door traffic packs frost into the gasket and inner-door seals, longer compressor runs follow, and the top shelf drifts away from the bottom one. Chart recorders need pens, paper, and calibration. Alarm setpoints and battery backup have to be tested, not assumed. We check all of it on every visit and document what we found.

What a repair visit includes

  • Diagnosis on site

    A blood bank unit is judged on uniformity and recovery, so we look at door traffic, gasket condition, and shelf-to-shelf spread as well as the setpoint, and we check the recorder against the probe.

  • The repair

    Compressors, evaporator and condenser fans, gaskets and inner-door seals, chart recorder drives and pens, alarm boards and batteries, and platelet agitator drives and controls.

  • Verification before we leave

    Alarm activation points verified, the chart recorder and probe calibrated against a NIST-traceable reference after the repair, and uniformity confirmed where your SOP requires it.

  • The record, and a straight answer

    A written record of what failed and what was done, and a plain repair-or-replace recommendation when a unit is past its useful life.

Response, rentals, and emergencies

A blood bank refrigerator alarming or a platelet agitator that has stopped is prioritized as an emergency. Rental blood bank refrigerators and plasma freezers are available so inventory moves once.

Inspection-ready records

We calibrate probes and recorders against NIST-traceable references, verify alarm activation points, and provide certificates and reports formatted for your quality system. When an inspector asks how you know the unit was in range, the answer is in your file.

Brands

Blood bank equipment brands we see most

Linked brands have their own page. Not on the list? Ask. We service most makes and models.

Guides

Reading on blood bank equipment

Written by our technicians: what to check, what the numbers mean, and when to call.

Where

Where we service blood bank equipment

Ten Southern California counties from our Huntington Beach headquarters, and beyond by arrangement.

Los Angeles, Orange, Riverside, San Bernardino, San Diego, and Ventura counties are our core area. Santa Barbara, San Luis Obispo, Kern, and Imperial counties are on a regular route. Equipment that is already down jumps the queue, and our line is answered 24/7.

Outside Southern California we work by arrangement for contract and long-standing customers, and we say plainly what we can do and how soon.

Also from one team

  • Calibration & Validation

    NIST-traceable calibration, IQ / OQ / PQ validation, and the certificates your auditors ask for.

  • Service & Repair

    Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.

  • Preventative Maintenance

    Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.

Blood bank equipment FAQs

Common questions

Can you calibrate blood bank refrigerators and chart recorders to AABB standards?

Yes. We calibrate temperature probes, displays, and chart recorders against NIST-traceable references and verify alarm activation, with certificates your AABB and FDA documentation can rely on.

Our platelet agitator stopped overnight. What happens now?

Call us: a stopped agitator is a regulatory event, not a nuisance. We prioritize blood bank calls and carry common drive and control parts.

Do you service plasma freezers that need manual defrost?

Yes, and we can schedule defrost and gasket work so it lands when your inventory is low.

Ready when you are

Blood bank equipment giving you trouble?

Request service online in under a minute, or call. Our line is answered 24/7.

24/7 emergency service · Dispatch confirms every request by phone.

Call nowRequest service

Request service

A few quick questions, then a dispatcher calls you to confirm.

What do you need?

Service type

Equipment failing right now? Don’t wait for a callback. 24/7 emergency service, and the line is answered 24/7.