Blood Bank Refrigerators, Plasma Freezers & Platelet Incubators
Blood bank refrigerators, plasma freezers, and platelet incubators, calibrated for AABB and FDA records.
Scheduled maintenance
The most expensive refrigeration failure is the one you didn’t see coming. Most cold storage failures trace back to a dirty condenser, a leaking gasket, a failing fan, or a controller that has drifted, and all four show themselves to a technician months before they take the product. A PM program puts that inspection on a schedule, keeps the record, and turns an unpredictable emergency into a budgeted visit.

Equipment failing right now? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.
A PM visit is an inspection and service of the parts that wear. It is not a repair, and it is not calibration; both can be bundled into the same visit when you want them.
Condenser cleaning on every visit, filter and fan check, and the clearance the unit needs to reject heat. Condenser cleaning is our task, not the customer’s.
Gasket condition and seal, hinge and latch adjustment, and the door heaters that keep frost off the frame.
Compressor sound and amperage, refrigerant pressures, evaporator and defrost operation, and the fans and motors that move the cold.
Controller settings, probe condition, alarm function, and battery backup checked against the unit’s spec. Calibration against a traceable reference is a separate task with its own record.
Connections, cords, and plugs inspected, and a written record of what was found, what was done, and what to watch, so the PM history tells you whether a unit is worth repairing when it finally fails.
Every six months is our standard contract offering and the baseline we recommend. Quarterly suits heavy use, which is common in California: a ULT freezer in a warm room, a unit with a door that opens all day. Annual is available but often not enough, and it is easier to start at six months or quarterly than to increase the interval later. We recommend a cadence per unit when we build the program.
A PM program is a recurring agreement scheduled around your facility. The basic checklist can be customized to your SOPs or expanded to cover anything not on it. Calibration, electrical safety testing, and alarm and backup testing can be bundled into the same visit, which saves a trip. Any recurring service agreement, whether PM, calibration, or electrical safety, qualifies you for our contracted-customer rates.
Calibration, certification & validationAny facility running critical temperature-control equipment: labs, hospitals, pharmaceutical and biotech operations, universities, and industrial sites. It pays off most where compliance documentation is required and where a failure costs more than the equipment.
By equipment
Every class of equipment fails in its own way. Pick yours for what we service, what goes wrong, and which brands we see most.
Blood bank refrigerators, plasma freezers, and platelet incubators, calibrated for AABB and FDA records.
Process chillers, circulators, and water baths that keep lasers, instruments, and reactors at temperature.
Mechanical cryogenic freezers, LN2 dewars, auto-fill systems, level controllers, and alarms.
Stability chambers and environmental test chambers for pharmaceutical, food, aerospace, automotive, and materials testing: repair, humidity systems, controller retrofits, and mapping.
Collector refrigeration, vacuum pumps, controls, and calibration for benchtop and console freeze dryers.
Medical-grade ice machines and dispensers: mechanical service plus scheduled cleaning and sanitizing.
CO2, refrigerated, BOD, and shaking incubators plus growth chambers, with temperature and CO2 calibration.
Drying, sterilizing, and industrial ovens and furnaces: uniformity surveys, repairs, and controller retrofits.
Pharmacy, vaccine, reagent, and chromatography refrigerators held to 2°C to 8°C and documented for inspection.
Reagent, enzyme, and sample freezers from -20°C to -40°C: repair, defrost systems, gaskets, and calibration.
The refrigeration system inside refrigerated centrifuges: compressor, condenser, and chamber control.
Cascade and Stirling -80°C freezers: repair, PM, calibration, CO2/LN2 backup, and rentals while yours is down.
Walk-in coolers and freezers, environmental rooms, and warm rooms: repair, mapping, and emergency response.
Preventative Maintenance FAQs
Every six months is our standard contract offering and the baseline we recommend. Quarterly suits heavy use. Annual is available but often not enough. We set a cadence per unit when we build the program.
Yes. We build recurring PM programs scheduled around your facility, customized to your SOPs, and any recurring agreement qualifies you for contracted-customer rates.
Calibration is a separate task with its own record. It is often done on the same visit and can be bundled into the program; see Calibration, certification & validation for what it covers.
Yes. Every visit produces a record of what was found and done, which supports audits, quality systems, and warranty requirements.
Also from one team
NIST-traceable calibration, IQ / OQ / PQ validation, and the certificates your auditors ask for.
Remote monitoring installed and serviced, CO2 and LN2 backup fitted and tested, battery backup load-tested.
Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.
Ready when you are
24/7 emergency service · Dispatch confirms every request by phone.