Service & Repair
Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.
Lab freezers · Repair & service
Enzyme and reagent freezers, sample freezers, and the -30°C and -40°C units that sit between a refrigerator and a ULT do quiet work until frost or a failed defrost takes them down. We repair upright and chest laboratory freezers, manual-defrost and auto-defrost, keep them within spec, and tell you when a unit has reached the end of its useful life.
Lab freezer warming or iced up? Call and dispatch triages it with you now. Or send an emergency request and a dispatcher calls you back.
Upright and chest laboratory freezers from -20°C to -40°C, auto-defrost and manual-defrost, in laboratory and medical grades.
Enzyme, reagent, media, and sample storage, upright and chest, auto-defrost and manual-defrost.
Single-stage deeper-cold units for samples and compounds that -20°C will not hold.
Defrost heaters, timers, termination thermostats, and drain lines on auto-defrost units.
Gaskets, door heaters, latches, controllers, probes, and alarm contacts wired to your monitoring.
Ice on the evaporator from a failed defrost heater or timer. Frost packed behind a worn gasket until the door no longer seals and the compressor runs continuously. A condenser packed with dust and a compressor that short-cycles. A probe that drifts and a display that lies. Most of these are fixable in one visit, and all of them are preventable with a maintenance schedule.
Defrost system, gasket and door seal, condenser airflow, and the probe are checked before the compressor, because a freezer that is icing is usually telling you which one.
Defrost heaters, timers, and drains, gaskets and door heaters, evaporator and condenser fans, controllers and probes, and compressors, with the common parts on hand.
Pull-down and hold verified at setpoint, defrost cycle watched through, alarms tested, and the display checked against a NIST-traceable reference.
A written record of what failed and what was done, and a plain repair-or-replace recommendation when a unit is past its useful life.
A freezer that is warming with reagents or samples inside is treated as an emergency: call, and dispatch triages it with you. Rental laboratory freezers are available, including 24-hour emergency placement, so the contents move once.
Laboratory cold storage runs in recognized tiers, and the freezer you need depends on what you store. This page covers the standard and low-temperature tier. The two colder tiers have their own pages, and the three reinforce each other rather than compete.
Routine reagents, enzymes, and some biologics. The upright and chest freezers on this page.
DNA, RNA, plasma, and vaccines, in cascade and Stirling -80°C freezers. Covered on the ULT freezer page.
Liquid nitrogen storage for living cells and long-term archives. Covered on the cryogenic and LN2 page.
A lab freezer PM is a condenser cleaning, a gasket and door check, a defrost-system check, a look at compressor amperage and cycle times, and a calibration of the display against a reference. On manual-defrost units we schedule the defrost and gasket work so it lands when your inventory is low.
Brands
Linked brands have their own page. Not on the list? Ask. We service most makes and models.
Guides
Written by our technicians: what to check, what the numbers mean, and when to call.
Calibration, validation, and temperature mapping mean different things. What each one proves, and which one your auditor is actually asking for.
The checklist behind a preventative maintenance visit on a lab refrigerator, freezer, or ULT freezer: each task, how often it is done, and which ones you can do in-house.
How to write a freezer alarm response plan that works at 3 a.m.: who is called, what they check, when product moves, and when to call for a rental.
Where
Ten Southern California counties from our Huntington Beach headquarters, and beyond by arrangement.
Los Angeles, Orange, Riverside, San Bernardino, San Diego, and Ventura counties are our core area. Santa Barbara, San Luis Obispo, Kern, and Imperial counties are on a regular route. Equipment that is already down jumps the queue, and our line is answered 24/7.
Outside Southern California we work by arrangement for contract and long-standing customers, and we say plainly what we can do and how soon.
Also from one team
Fast diagnosis and expert fixes, 24 hours a day, on virtually any make or model.
Scheduled upkeep on a cadence that fits each unit, so wear is found on a visit instead of as downtime.
New and used rental units, including 24-hour emergency availability when a unit goes down.
Lab freezers FAQs
Usually a repair: a failed defrost heater, timer, or drain, or a gasket that is letting moist air in. It is also the first sign the compressor is working harder than it should, so it is worth fixing early.
Manual-defrost holds temperature more steadily because it never warms to shed frost, which suits enzymes and sensitive reagents. Auto-defrost is convenient for general storage. We will say plainly which your contents need.
Yes. Rental laboratory freezers are available, including 24-hour emergency placement.
Ready when you are
Request service online in under a minute, or call. Our line is answered 24/7.
24/7 emergency service · Dispatch confirms every request by phone.