Maintenance Interval Planner
Preventative maintenance only works when it is scheduled. Select the equipment classes in your facility and how many of each, and the planner lays out the typical service tasks by interval so you can see the year in one table and hand it to whoever owns the calendar.
Read this first.
Intervals shown are the cadence we recommend from service practice, for planning purposes. The manufacturer’s manual and your SOPs govern where they differ.
The figures on this page are industry averages, shown for example purposes. Your equipment, its age and condition, the room it sits in, and how it is used all change the real numbers, and units are often repurposed beyond their original design. Scientific Refrigeration accepts no liability for decisions made from these estimates. Do your own research for your application, follow your SOPs and the manufacturer’s manual, and keep a backup plan for stored product; that plan is your responsibility.
Equipment in your facility
Enter how many of each you have. Leave the rest blank.
Your year of maintenance
Units covered
6
PM visits per year
2
Our task events per year
18
| Interval | Equipment | Task | Who |
|---|---|---|---|
| Quarterly | Ultra-low freezers × 2 | Alarm, battery backup, and CO2/LN2 backup test per your SOP | Your team |
| Lab and pharmacy refrigerators and freezers × 4 | Alarm and data logger check | Your team | |
| Every 6 months | Ultra-low freezers × 2 | PM visit: condenser and filter cleaned, gasket, inner doors, latch, door heater, controls, refrigeration performance | Us |
| Lab and pharmacy refrigerators and freezers × 4 | PM visit: condenser cleaned, door seal and closing, fans, drain, controls | Us | |
| Annually | Ultra-low freezers × 2 | Temperature probe calibration against a NIST-traceable reference (bundled with a PM visit) | Us |
| Lab and pharmacy refrigerators and freezers × 4 | Temperature probe calibration (bundled with a PM visit) | Us |
Want this on our calendar instead of yours? A preventative maintenance program covers every “Us” row in this table under one agreement.
Every six months is our standard contract and the baseline we recommend; California facilities with heavy use do better on a quarterly cadence, and annual is offered but is often not enough. Calibration is typically annual and is bundled into a PM visit, which is cheaper than arranging it separately. Any recurring agreement (PM, calibration, maintenance, or electrical safety) qualifies you for contracted-customer rates.
Go deeper
Guides on the same equipment
- 5 min read
Blood bank refrigeration: temperature, alarms, and records
What blood bank refrigerators, plasma freezers, and platelet incubators have to do that ordinary lab units do not, and the records an inspector expects to see.
- 5 min read
Calibration, validation, and mapping: what each one is and when you need it
Calibration, validation, and temperature mapping mean different things. What each one proves, and which one your auditor is actually asking for.
- 5 min read
CO2 incubator care: contamination, calibration, and recovery
Keeping a CO2 incubator at 37°C and the right gas mix: cleaning that prevents contamination, calibrating temperature and CO2, and recovering after a failure.